Background Image
Table of Contents Table of Contents
Previous Page  156 / 365 Next Page
Information
Show Menu
Previous Page 156 / 365 Next Page
Page Background

© 2014 Foundation Supportworks

®

,

Inc.

All Rights Reserved

p 156

APPENDIX 2F

MODEL SPECIFICATIONS

Chapter 2

Helical Foundation Systems

3.1.17 Load Factor: A factor that accounts for the probability of deviation of the actual load

from the predicted nominal load due to variability of material properties, workmanship,

type of failure and uncertainty in the prediction of the load (Load and Resistance Factor

Design).

3.1.18 Load Test: A process to test the ultimate anchor capacity and relation of applied load to

anchor head movement by application of a known load on the helical anchor head and

monitoring movement over a specific time period.

3.1.19 Loads: Forces that result from the weight of all building materials, occupants and their

possessions, environmental effects, differential movement, and restrained dimensional

changes. Permanent loads are those loads in which variations over time are rare or of

small magnitude. All other loads are variable loads (see also Nominal Loads).

3.1.20 Mechanical Strength: The maximum load or the load at a specified limit state that can

be resisted by the structural elements of a helical anchor.

3.1.21 Net Deflection: The total movement at the anchor head minus the theoretical elastic

deformation of the anchor shaft during a load test.

3.1.22 Nominal Loads: The magnitude of the loads specified, which include dead, live, soil,

wind, snow, rain, flood and earthquakes (also referred to as service loads or working

loads).

3.1.23 Nominal Resistance: The anchor capacity at a specified ultimate limit state (Load and

Resistance Factor Design). See Ultimate Anchor Capacity.

3.1.24 Nominal Strength: A term used in structural design which is defined as the structure or

member capacity at a specified strength limit state. See Ultimate Anchor Capacity.

3.1.25 Resistance Factor: A factor that accounts for the probability of deviation of the actual

resistance (strength) from the predicted nominal resistance (strength) due to variability

of material properties, workmanship, type of failure and uncertainties in the analysis

(Load and Resistance Factor Design).

3.1.26 Service Loads: See “Nominal Loads” above.

3.1.27 Ultimate Anchor Capacity: The helical anchor capacity based on the least capacity

determined from applicable ultimate limit states for mechanical and geotechnical

capacity.

4

APPROVED HELICAL ANCHOR MANUFACTURERS

4.1 Foundation Supportworks

®

, Inc., 12330 Cary Circle, Omaha, NE 68128; Phone: (800) 281-8545;

Fax: (402) 393-4002.

4.2 Due to the special requirements for design and manufacturing of helical anchors, the anchors

shall be obtained from Foundation Supportworks

®

, Inc., or other qualified manufacturer with an

approved equivalent product. A request to substitute any other manufactured helical product

must be submitted to the Owner for review not less than seven (7) calendar days prior to the bid

date. The request must include: