APPENDIX 2A

HELICAL PRODUCT RATINGS, PROPERTIES AND DETAILS

Chapter 2

Helical Foundation Systems

Plain

Plain

Corroded

(1)

Galvanized

Corroded

(1,2)

OD (in)

3.500

3.464

3.490

t (in)

0.316

0.28

0.306

ID (in)

2.868

2.904

2.876

A (in

2

)

3.16

2.80

3.06

I (in

4

)

4.05

3.58

3.91

S (in

3

)

2.31

2.07

2.24

Z (in

3

)

3.21

2.85

3.11

r (in)

1.13

1.13

1.13

Shaft Max Allowable Compression Capacity

(4,5)

P

n

/Ω (kips)

118.5

105.0

114.8

Shaft Max Allowable Tension Capacity

(5)

P

n

/Ω (kips)

73.0

62.8

69.1

HP350 Shaft Specifications and Capacities

Shaft Material:

Ø

3.500” x 0.340” wall

ASTM A500 Grade B or C

Yield strength = 65 ksi (min)

Tensile strength = 75 ksi (min)

Shaft Coupler Material:

Ø

4.250” x 0.344” wall

ASTM A513 Type 5 Grade 1026

Yield strength = 70 ksi (min)

Tensile strength = 80 ksi (min)

Helix Plates:

ASTM A572 Grade 50 material

3/8

” thick (standard)

1

” thick (available)

Helix plate geometry conforming to

ICC-ES AC358

Shaft Coupling Hardware:

(4) -

Ø

1” Grade 5 bolts with nuts

Electrozinc plated per ASTM B633

Surface Finish of Shaft

Segments:

Available plain or hot-dip galvanized

(2)

Nominal Thickness

0.340 (in)

Design Thickness

(3)

0.316 (in)

Default Torque Correlation Factor

(6)

K

t

= 7 (ft

-1

)

Maximum Ultimate Soil Capacity

(7)

Q

u

= 122.5 (kips)

Maximum Installation Torque T = 17,500 (ft-lb)

Maximum Allowable Soil Capacity

(7)

Q

a

= 60.0 (kips) FOS = 2.04

(1)

Corroded properties and capacities include a 50-year scheduled sacrificial loss in thickness per ICC-ES AC358.

(2)

Hot-dip galvanized coating in accordance with ASTM A123.

(3)

Design thickness for HSS and Pipe based on 93% of nominal thickness per AISC.

(4)

Allowable mechanical compression capacities consider continuous lateral soil confinement in soils with SPT blow counts ≥ 4. Piles with

exposed unbraced lengths or piles placed in weaker or fluid soils should be evaluated on a case by case basis by the project engineer.

(5)

Listed mechanical capacities are for the shaft and coupled connections only. System capacity should also not exceed the installed allowable

torque-correlated soil capacity or the allowable capacity of the respective bracket (see additional bracket tables).

(6)

Listed default K

t

factor is consistent with that listed in ICC-ES AC358. This value is generally conservative. Site-specific K

t

factors can be

determined for a given project with full-scale load testing.

(7)

Soil capacities listed are at maximum installation torque. Ultimate soil capacity is based on the equation Q

u

= K

t

x T. Allowable soil capacity is

obtained by dividing the ultimate capacity by an appropriate factor of safety, but should not exceed 60 kips per AC358. Although a factor of

safety of 2.0 is commonly used, a higher or lower factor of safety may be considered at the discretion of the helical pile designer or as dictated

by local code requirements. System capacity should also not exceed the mechanical capacity of the shaft or those listed in the respective

bracket capacity tables.

Rev. 10/14/16