APPENDIX 2A

HELICAL PRODUCT RATINGS, PROPERTIES AND DETAILS

Chapter 2

Helical Foundation Systems

HP350B Bracket Specifications and Capacities

when used with the HP350 Helical Pile System

Bracket:

Weldment manufactured from

3/8

” and

1

ASTM A36 plate.

Concrete Anchorage

(7)

(Optional):

(6) -

Ø

5/8

” x 9” long all-thread rod

Grade B7, tensile strength = 125 ksi (min)

Electrozinc plated per ASTM B633

Cap Plate:

1-

1

” x 4.00” x 8.50” ASTM A572 Grade 50

with capture plate welded to one side.

Bracket Hardware:

(2) -

Ø

7/8

” x 18” long all-thread rod

Grade B7, tensile strength = 125 ksi (min)

Electrozinc plated per ASTM B633

Bracket Finish:

Available plain or hot-dip galvanized

(2)

Allowable Bracket Capacity

(3,4,5,6)

R

n

NO Adhesive

Anchors

(kips)

WITH Adhesive

Anchors

(7)

(kips)

Plain

36.5

45.0

Plain Corroded

(1)

32.6

40.2

Galvanized

Corroded

(1,2)

35.4

43.7

(1)

Corroded capacities include a 50-year scheduled sacrificial loss in thickness per ICC-ES AC358.

(2)

Hot-dip galvanized coating in accordance with ASTM A123.

(3)

Brackets shall be used for support of structures that are considered to be fixed from translation. Structures that are not fixed from translation

shall be braced in some manner prior to installing retrofit brackets systems.

(4)

Allowable capacities consider continuous lateral soil confinement in soils with SPT blow counts ≥ 4. Piles with exposed unbraced lengths or piles

placed in weaker or fluid soils should be evaluated on a case by case basis by the project engineer.

(5)

Concrete bearing assumes a minimum compressive strength (f’c) of 2,500 psi. Local concrete bending and other local design checks should

be evaluated on a case by case basis by the project engineer.

(6)

Listed allowable capacities are for the specific shaft/bracket combination shown. System capacity should also not exceed the installed

torque-correlated soil capacity (See Shaft Specifications and Capacities).

(7)

Specified anchors installed to a minimum embedment of 7.5” into concrete with a minimum compressive strength f’c = 2,500 psi utilizing

Simpson AT adhesive.