APPENDIX 3B

DRIVE STAND SPECIFICATIONS

Chapter 3

Hydraulically-Driven Push Piers

Model 238 Drive Stand Specifications

when used with the RED

(4)

Drive Cylinder (FS35DC)

Compatible Brackets

(3)

:

FS238B

Drive Cylinder

(4)

(FS35DC):

Stroke = 22”

Cylinder action = double

Bore =

Ø

3.50”

Hydraulic area = 9.62 in

2

Max operating pressure

(2)

= 8,000 psi

Drive Cylinder Adaptor:

FSDCA238

Drive Stand Hardware

(1)

:

(1) -

Ø

3/4

” x 12” long coil rod with nuts

(2) -

Ø

5/8

” x 12” long coil rods with nuts

(4) - 1-

1

” Flanged Pins

Drive Stand Rated Drive Load

(2,3)

30.0 kips

Hydraulic

Pressure

(psi)

Drive

Force

(2,3)

(kips)

Hydraulic

Pressure

(psi)

Drive

Force

(2,3)

(kips)

200

1.9

2,100

20.2

400

3.8

2,200

21.2

600

5.8

2,300

22.1

800

7.7

2,400

23.1

1,000

9.6

2,500

24.1

1,200

11.5

2,600

25.0

1,400

13.5

2,700

26.0

1,600

15.4

2,800

26.9

1,700

16.4

2,900

27.9

1,800

17.3

3,000

28.9

1,900

18.3

3,100

29.8

2,000

19.2

3,120

30.0

(1)

Drive stand should never be operated without all hardware components firmly in place.

(2)

Do not operate at pressures that produce drive forces in excess of the drive stand’s rated drive load. Max operating pressure of the drive

cylinder produces forces that exceed this value and is given for informational purposes only.

(3)

Do not operate at pressures that produce drive forces in excess of the “maximum drive force during installation” values specified for the

bracket being installed (see Bracket Specifications and Capacities).

(4)

Note that the mounting flange dimensions are different between the RED and GRAY cylinders (FS35DC and FS425DC) and thereby require

the use of unique top fixture weldments that correspond to the appropriate drive cylinder.