APPENDIX 4C

CARBONARMOR® WALL REINFORCING SYSTEM

Chapter 4

Miscellaneous Structural Support Products

CarbonArmor

®

Wall Reinforcing System

Technical Specifications of Carbon Composite

Tensile Strength:

Design Value = 121.7 ksi, Test method in accordance with ASTM D3039

Modulus of Elasticity:

Design Value = 10,401.7 ksi, Test method in accordance with ASTM D3039

Effective Ply Thickness:

0.062 inches

Strap Width:

7 inches

CarbonArmor

®

Wall Reinforcing System

Technical Specifications of Saturant Epoxy

Tensile Strength:

9-10 ksi

Tensile Modulus:

441.7 ksi

Elongation at Break Percentage:

4.99%

Flexural Strength:

417.1 ksi

Note:

Material Safety Data Sheets (MSDS) for the

CarbonArmor

carbon fabric, saturating resin and saturating

hardener are available upon request.

Spacing Recommendations:

CarbonArmor

®

spacing tables have been determined with consideration for the recommendations of ACI 440, design

calculations, and current industry state of practice. The carbon straps are to be installed per the installation instructions and

must be the full height of the wall.

8” Masonry Block Wall Height (ft.)

5

6

7

8

9

10

Unbalanced fill Height (ft.)

5

5.0

5.0

5.0

5.0

5.0

5.0

6

5.0

5.0

5.0

5.0

5.0

7

5.0

4.5

4.0

3.5

8

3.5

3.0

2.5

9

2.5

2.5

10

2.5

Rendering of the CarbonArmor

®

system

installed within a basement

Rev. 5/26/16