Background Image
Table of Contents Table of Contents
Previous Page  255 / 365 Next Page
Information
Show Menu
Previous Page 255 / 365 Next Page
Page Background

© 2014 Foundation Supportworks

®

,

Inc.

All Rights Reserved

p 255

APPENDIX 3A

BRACKET SPECIFICATIONS AND CAPACITIES

Chapter 3

Hydraulically-Driven Push Piers

Bracket:

Weldment manufactured from

1

and

3/8

” ASTM A36 plate.

Pier Tube:

Ø

2.375” x 0.154” wall x 36” long

ASTM A500 Grade B or C

Yield strength = 60 ksi (min)

Tensile strength = 70 ksi (min)

Available plain or hot-dip galvanized

(2)

Pier Tube Coupler:

Ø

2.000” x 0.187” wall x 5” long

FS238B Bracket Specifications and Capacities

when used with the PP237 Push Pier System

Allowable Bracket Capacity

(4,5,6,7)

R

n

with 30”

Sleeve

(kips)

with 48”

Sleeve

(kips)

Plain

13.0

17.0

Plain Corroded

(1)

9.9

12.9

Galvanized Corroded

(1)

12.1

15.9

Maximum Drive Force

During Installation

(7)

22.1

28.9

(1)

Corroded capacities include a 50-year scheduled sacrificial loss

in thickness per ICC-ES AC406.

(2)

Hot-dip galvanized coating in accordance with ASTM A123.

(3)

Optional hardware utilizes similar sized all-thread made from

Grade B7, tensile strength = 125 ksi.

(4)

Brackets shall be used for support of structures that are

considered to be fixed from translation. Structures that are not

fixed from translation shall be braced in some manner prior to

installing retrofit brackets systems.

(5)

Allowable compression capacities consider continuous lateral

soil confinement in soils with SPT blow counts ≥ 4. Piers with

exposed unbraced lengths or piers placed in weaker or fluid

soils should be evaluated on a case by case basis by the project

engineer.

(6)

Concrete bearing assumes a minimum compressive strength

(f’c) of 2,500 psi. Local concrete bending and other local design

checks should be evaluated on a case by case basis by the

project engineer.

(7)

Push Piers shall be installed with a driving force exceeding the

required allowable service load by a sufficient factor of safety

(FOS). FOS is most commonly between 1.5 and 2.0, although

a higher or lower FOS may be considered at the discretion

of the pier designer or as dictated by local code or project

requirements.

Pier Starter Tube:

Pier tube section with

Ø

2.875” friction

reduction collar welded at leading end.

External Sleeve:

Ø

2.875” x 0.203” wall x 30” or x 48” long

with welded collar at one end.

ASTM A500 Grade B or C

Yield strength = 60 ksi (min)

Tensile strength = 70 ksi (min)

Cap Plate:

3/4

” x 3.75” x 5.75” ASTM A572 Grade 50

with confining ring welded to one side.

Bracket Hardware

(3)

:

(2) -

Ø

5/8

”x 16” long contour (coil) rod

AISI 1045, tensile strength = 120 ksi (min)

Electrozinc plated per ASTM B633

Bracket Finish:

Available plain or hot-dip galvanized

(2)

Rev. 5/26/15