Chapter 2

Helical Foundation Systems

CHAPTER 2

HELICAL FOUNDATION SYSTEMS

2.7.2 Cylindrical Shear Method

The design equation for determining helical pile

capacity by the cylindrical shear method was

originally developed by Mitsch and Clemence

(1985) and later modified for simplicity.

The cylindrical shear method assumes the

development of a soil friction column (cylinder)

between the upper and lower helix plates along

with individual bearing of either the upper or

lower helix, depending upon loading direction.

The ultimate bearing capacity is then determined

by the summation of shear strength of the soil

cylinder, shaft adhesion/friction and end bearing

of either the upper or lower helix. For deep

cylindrical shear failure to occur, spacing of the

helix plates along the shaft is generally less than

or equal to 3 times the diameter of the leading

plate and the uppermost helix plate is embedded

to a depth of at least 5 diameters. Skin friction

along the shaft is generally ignored for shaft

sizes less than 6 inches in outside diameter.

Figure 2.7.2.a

illustrates the load transfer

mechanism for the cylindrical shear method in

compression loading.

The helical pile capacity by the cylindrical shear

method can be calculated as:

Q

u

= 2πRL(c+K

o

q’tanΦ)+A

h

(cN

c

+q’N

q

)

Where,

Q

u

= Ultimate Pile Capacity (lb)

R

= Average Helix Radius (ft)

L

= Total Spacing Between All Helix

Plates (ft)

c

= Cohesion at the Helix Depth (lb/ft

2

)

K

o

= Dimensionless At-Rest Earth

Pressure Coefficient

Φ

= Soil Friction Angle (degrees)

A

h

= Area of the Top or Bottom Helix

Plate (ft

2

)

q’

= Effective Vertical Overburden Stress

at A

h

(lb/ft

2

)

N

c

, N

q

= Dimensionless Bearing Capacity

Factors

Refer to Section 2.7.1 for discussions

regarding Bearing Capacity Factors and

Critical Depth.

Based upon previous research, the individual

bearing method and cylindrical shear method

should provide similar results at helix spacings

of 2.5D to 3.5D. FSI promotes the use of the

individual bearing method for determination of

pile capacity due to its relative simplicity and

since the original form from which this method

is derived is already widely accepted by the

geotechnical engineering community.

Figure 2.7.2.a

Cylindrical Shear Method