Chapter 4
Miscellaneous Structural Support Products
CHAPTER 4
MISCELLANEOUS STRUCTURAL SUPPORT PRODUCTS
Step4
–Strap isadhered to theprepared foundation
wall
(Figure 4.4.2.1.a4)
. See Step 1 of Section 4.4.2
for wall preparation recommendations.
Step 5
– CarbonArmor strap is installed over
and bonded to the ArmorLock by saturating
both with epoxy
(Figure 4.4.2.1.a5)
.
Step 6
– Installation of CarbonArmor Wall
Reinforcing System with optional ArmorLock
system complete
(Figure 4.4.2.1.a6)
.
4.4.2.2 Special Installation
Considerations
• Do not apply to concrete less than 30 days old.
• Do not apply to concrete with curing or sealing
membranes.
• Do not apply to concrete with a surface
temperature less than 45°F.
• Do not thin epoxy with solvent.
• High temperature environments may require
a special hardener selection. Consult with a
FSI representative for recommendations in
these situations.
Figure 4.4.2.1.a4
Figure 4.4.2.1.a5
Figure 4.4.2.1.a6